Managed Hosting

The Services you need wrapped in the Expert Support you want.

 

Web Teks provides the world-class infrastructure necessary to maintain our dedicated Web servers 24x7. We operate our US data centers out of Chesapeake, Virginia and San Antonio, Texas. Our data centers have been engineered to avoid any single point of failure in our connectivity, power, or HVAC. And because our data centers are not open to the public, you can rest assured that only a handful of highly trained, level-three technicians will be allowed within close physical proximity to your server.
 
 

Physical Security

The data centers are physically isolated from everyone but level three technicians. Public access is strictly forbidden. Access to the data center floors is restricted to those holding military-grade pass cards. Furthermore, access to the data centers themselves is restricted by Biometric hand scanners.                      
    
 

Location

San Antonio is an ideal location for our primary data center because of the absence of natural disasters. This is on the most seismically stable soil in the US. In fact, San Antonio is one of only two places in the US that Lloyd's of London will underwrite for earthquake insurance. Additionally, the absence of hurricanes and tornadoes make the Web Teks data center the perfect location for your mission-critical data.  
 
 

Conditioned Power

Power systems in our data centers are designed to run uninterrupted even in the unlikely event of a total power outage. All servers are fed with conditioned UPS (Uninterruptible Power Supply) power that will run if utility power fails. The UPS power subsystem is N+1 redundant with instantaneous failover in case the primary UPS fails. In the event of an extended power outage, an on-site diesel generator can run indefinitely. The generator is regularly tested to ensure that it will continue to function in the event of an emergency.                               
 
 

A Precision Environment

Our data centers are meticulously tidy. All air is circulated and filtered every 90 seconds to remove dust and contaminants. The data center's HVAC (Heating Ventilation Air Conditioning) system is N+1 redundant to ensure that - even in the event of an entire HVAC system failure - there is a duplicate system on standby to take over. An advanced fire-suppression system is in place to prevent any fire from spreading - in the unlikely event that one could start. All cables to servers and routing equipment are securely tied down, and cable racks suspended from the ceiling provide dual routes for all cables. In the event that all cables on a cable rack are cut or burned, packets of data will automatically be routed to a second set of cables on the other side of the data center.
 